| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1769652160 | 547 Count | 979 Count | 348 Count | 0 VDC | 0 VDC |
| 1769651257 | 544 Count | 974 Count | 346 Count | 0 VDC | 0 VDC |
| 1769650353 | 542 Count | 970 Count | 345 Count | 0 VDC | 0 VDC |
| 1769649449 | 540 Count | 964 Count | 344 Count | 0 VDC | 0 VDC |
| 1769648545 | 538 Count | 961 Count | 343 Count | 0 VDC | 0 VDC |
| 1769647642 | 535 Count | 953 Count | 341 Count | 0 VDC | 0 VDC |
| 1769646738 | 532 Count | 945 Count | 339 Count | 0 VDC | 0 VDC |
| 1769644930 | 526 Count | 935 Count | 335 Count | 0 VDC | 0 VDC |
| 1769644027 | 523 Count | 931 Count | 333 Count | 0 VDC | 0 VDC |
| 1769643123 | 520 Count | 926 Count | 331 Count | 0 VDC | 0 VDC |
| 1769642219 | 517 Count | 921 Count | 329 Count | 0 VDC | 0 VDC |
| 1769641320 | 514 Count | 916 Count | 327 Count | 0 VDC | 0 VDC |
| 1769640416 | 511 Count | 912 Count | 325 Count | 0 VDC | 0 VDC |
| 1769639598 | 508 Count | 907 Count | 323 Count | 0 VDC | 0 VDC |
| 1769638694 | 505 Count | 902 Count | 321 Count | 0 VDC | 0 VDC |
| 1769637790 | 502 Count | 890 Count | 319 Count | 0 VDC | 0 VDC |
| 1769636887 | 499 Count | 883 Count | 317 Count | 0 VDC | 0 VDC |
| 1769635983 | 496 Count | 878 Count | 315 Count | 0 VDC | 0 VDC |
| 1769635079 | 493 Count | 873 Count | 313 Count | 0 VDC | 0 VDC |
| 1769634175 | 490 Count | 866 Count | 311 Count | 0 VDC | 0 VDC |
| 1769633272 | 487 Count | 863 Count | 309 Count | 0 VDC | 0 VDC |
| 1769632368 | 484 Count | 859 Count | 307 Count | 0 VDC | 0 VDC |
| 1769631464 | 481 Count | 855 Count | 305 Count | 0 VDC | 0 VDC |
| 1769630561 | 478 Count | 848 Count | 303 Count | 0 VDC | 0 VDC |
| 1769629657 | 475 Count | 843 Count | 301 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)