This is the latest recevied telemetry packets stored in our database for station/object CRAIG-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Line* | PV* | Battery* | Batt-Temp* | Pi-Temp* |
|---|---|---|---|---|---|
| 1791085275 | 32.5 Volts | 12.99 Volts | 12.99 Volts | 63 Deg.F | 116 Deg.F |
| 1791084675 | 32.5 Volts | 12.99 Volts | 13 Volts | 63 Deg.F | 116 Deg.F |
| 1791084075 | 32.5 Volts | 13 Volts | 13 Volts | 64 Deg.F | 116 Deg.F |
| 1791083475 | 32.5 Volts | 13 Volts | 13 Volts | 64 Deg.F | 118 Deg.F |
| 1791082875 | 32.5 Volts | 13.01 Volts | 13.01 Volts | 65 Deg.F | 118 Deg.F |
| 1791082274 | 32.5 Volts | 13.02 Volts | 13.01 Volts | 65 Deg.F | 118 Deg.F |
| 1791081675 | 32.5 Volts | 13.02 Volts | 13.02 Volts | 66 Deg.F | 120 Deg.F |
| 1791081075 | 32.5 Volts | 13.03 Volts | 13.03 Volts | 67 Deg.F | 120 Deg.F |
| 1791080475 | 32.5 Volts | 13.03 Volts | 13.03 Volts | 68 Deg.F | 122 Deg.F |
| 1791079875 | 32.5 Volts | 13.04 Volts | 13.04 Volts | 68 Deg.F | 123 Deg.F |
| 1791079275 | 32.5 Volts | 13.04 Volts | 13.04 Volts | 69 Deg.F | 125 Deg.F |
| 1791078675 | 32.5 Volts | 13.05 Volts | 13.05 Volts | 70 Deg.F | 125 Deg.F |
| 1791078075 | 32.5 Volts | 13.06 Volts | 13.06 Volts | 72 Deg.F | 127 Deg.F |
| 1791077475 | 32.5 Volts | 13.06 Volts | 13.06 Volts | 73 Deg.F | 129 Deg.F |
| 1791076875 | 32.5 Volts | 13.06 Volts | 13.07 Volts | 74 Deg.F | 131 Deg.F |
| 1791076275 | 32.5 Volts | 13.07 Volts | 13.08 Volts | 75 Deg.F | 134 Deg.F |
| 1791075675 | 32.5 Volts | 13.07 Volts | 13.08 Volts | 77 Deg.F | 136 Deg.F |
| 1791075075 | 32.5 Volts | 13.07 Volts | 13.08 Volts | 79 Deg.F | 140 Deg.F |
| 1791074475 | 32.5 Volts | 13.09 Volts | 13.09 Volts | 81 Deg.F | 140 Deg.F |
| 1791073875 | 32.5 Volts | 13.1 Volts | 13.1 Volts | 83 Deg.F | 141 Deg.F |
| 1791073275 | 32.5 Volts | 13.1 Volts | 13.11 Volts | 85 Deg.F | 145 Deg.F |
| 1791072675 | 32.5 Volts | 13.12 Volts | 13.12 Volts | 87 Deg.F | 145 Deg.F |
| 1791072075 | 32.5 Volts | 13.12 Volts | 13.13 Volts | 88 Deg.F | 145 Deg.F |
| 1791071476 | 32.5 Volts | 13.14 Volts | 13.14 Volts | 89 Deg.F | 143 Deg.F |
| 1791071125 | 32.5 Volts | 13.16 Volts | 13.16 Volts | 89 Deg.F | 138 Deg.F |
*Used Equation Coefficients:
Line: 0, 0.01, 0
PV: 0, 0.01, 0
Battery: 0, 0.01, 0
Batt-Temp: 0, 1, 0
Pi-Temp: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)