This is the latest recevied telemetry packets stored in our database for station/object SP9WJ-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | current* | temp* | humidity* | v batt* | v cpu* |
---|---|---|---|---|---|
1740209637 | 1.27 mA | 0 C | 63 % | 1.22 V | 3.28 V |
1740209504 | 1.27 mA | 0 C | 63 % | 1.22 V | 3.28 V |
1740208716 | 1.07 mA | 0 C | 65 % | 1.22 V | 3.26 V |
1740208573 | 1.07 mA | 0 C | 66 % | 1.2 V | 3.28 V |
1740207795 | 1.18 mA | 0 C | 69 % | 1.2 V | 3.28 V |
1740207662 | 1.18 mA | -1 C | 70 % | 1.2 V | 3.28 V |
1740206741 | 1.77 mA | -2 C | 74 % | 1.18 V | 3.26 V |
1740205955 | 1.33 mA | -3 C | 78 % | 1.18 V | 3.28 V |
1740205034 | 1.38 mA | -3 C | 80 % | 1.15 V | 3.28 V |
1740204114 | 1.37 mA | -3 C | 79 % | 1.15 V | 3.26 V |
1740202273 | 1.52 mA | -3 C | 78 % | 1.15 V | 3.28 V |
1740201353 | 1.74 mA | -3 C | 77 % | 1.18 V | 3.28 V |
1740200433 | 1.57 mA | -3 C | 77 % | 1.18 V | 3.28 V |
1740199512 | 1.37 mA | -3 C | 79 % | 1.15 V | 3.28 V |
1740197671 | 2.32 mA | -3 C | 78 % | 1.15 V | 3.28 V |
1740196751 | 1.96 mA | -3 C | 78 % | 1.18 V | 3.28 V |
1740195831 | 1.37 mA | -3 C | 79 % | 1.15 V | 3.28 V |
1740194911 | 1.57 mA | -3 C | 78 % | 1.18 V | 3.28 V |
1740193990 | 1.73 mA | -2 C | 76 % | 1.18 V | 3.26 V |
1740193070 | 2.7 mA | -2 C | 77 % | 1.18 V | 3.28 V |
1740192150 | 1.9 mA | -2 C | 78 % | 1.18 V | 3.28 V |
1740191230 | 2.35 mA | -2 C | 77 % | 1.18 V | 3.28 V |
1740190309 | 2.35 mA | -2 C | 76 % | 1.18 V | 3.28 V |
1740189389 | 1.51 mA | -2 C | 77 % | 1.18 V | 3.28 V |
1740188469 | 1.58 mA | -2 C | 77 % | 1.18 V | 3.28 V |
*Used Equation Coefficients:
current: 0, 0.01569, 0
temp: 0, 1, -128
humidity: 0, 1, 0
v batt: 0, 0.02353, 0
v cpu: 0, 0.01569, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)