This is the latest recevied telemetry packets stored in our database for station/object SQ2CPA-2. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1775237843 | 269 Count | 548 Count | 228 Count | 4.08 VDC | 0.68 VDC |
| 1775236045 | 262 Count | 531 Count | 222 Count | 4.08 VDC | 5.5 VDC |
| 1775234248 | 254 Count | 516 Count | 215 Count | 4.08 VDC | 5.5 VDC |
| 1775232450 | 247 Count | 504 Count | 209 Count | 4.08 VDC | 5.5 VDC |
| 1775230654 | 240 Count | 491 Count | 203 Count | 4.08 VDC | 5.5 VDC |
| 1775228856 | 233 Count | 476 Count | 197 Count | 4.08 VDC | 5.52 VDC |
| 1775227058 | 226 Count | 462 Count | 191 Count | 4.09 VDC | 5.52 VDC |
| 1775225259 | 218 Count | 448 Count | 184 Count | 4.09 VDC | 5.52 VDC |
| 1775223462 | 211 Count | 437 Count | 178 Count | 4.09 VDC | 5.52 VDC |
| 1775221664 | 204 Count | 425 Count | 172 Count | 4.1 VDC | 5.52 VDC |
| 1775219867 | 198 Count | 415 Count | 167 Count | 4.1 VDC | 5.52 VDC |
| 1775218069 | 191 Count | 402 Count | 161 Count | 4.1 VDC | 5.54 VDC |
| 1775216270 | 183 Count | 386 Count | 154 Count | 4.1 VDC | 5.52 VDC |
| 1775214471 | 176 Count | 374 Count | 148 Count | 4.1 VDC | 5.5 VDC |
| 1775212674 | 169 Count | 362 Count | 142 Count | 4.1 VDC | 5.5 VDC |
| 1775210877 | 162 Count | 350 Count | 136 Count | 4.11 VDC | 5.52 VDC |
| 1775209079 | 155 Count | 338 Count | 130 Count | 4.11 VDC | 5.5 VDC |
| 1775207281 | 147 Count | 325 Count | 123 Count | 4.11 VDC | 5.5 VDC |
| 1775205483 | 140 Count | 312 Count | 117 Count | 4.13 VDC | 5.5 VDC |
| 1775203685 | 133 Count | 301 Count | 111 Count | 4.17 VDC | 5.5 VDC |
| 1775201890 | 127 Count | 295 Count | 106 Count | 4.15 VDC | 5.48 VDC |
| 1775200093 | 121 Count | 289 Count | 101 Count | 4.11 VDC | 4.52 VDC |
| 1775198295 | 114 Count | 273 Count | 95 Count | 4.05 VDC | 5.5 VDC |
| 1775196497 | 107 Count | 259 Count | 89 Count | 4.05 VDC | 4.4 VDC |
| 1775194699 | 100 Count | 245 Count | 83 Count | 4.04 VDC | 4.38 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)