This is the latest recevied telemetry packets stored in our database for station/object WA6ODP-2. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | DC* | PC Board* | CPU* | Ambient* | Value5* |
|---|---|---|---|---|---|
| 1765029995 | 1327 | 75.5 | 43.5 | 56.4 | 0 |
| 1765029429 | 1324 | 75.5 | 43.5 | 56.5 | 0 |
| 1765028795 | 1325 | 75.6 | 42.9 | 56.5 | 0 |
| 1765028231 | 1327 | 75.6 | 42.9 | 56.5 | 0 |
| 1765027594 | 1325 | 75.8 | 42.9 | 56.6 | 0 |
| 1765027031 | 1325 | 75.8 | 43.5 | 56.6 | 0 |
| 1765026395 | 1328 | 75.8 | 43.5 | 56.6 | 0 |
| 1765025829 | 1325 | 75.9 | 44 | 56.6 | 0 |
| 1765025195 | 1327 | 75.8 | 43.5 | 56.6 | 0 |
| 1765024630 | 1328 | 75.9 | 44 | 56.6 | 0 |
| 1765023995 | 1330 | 75.9 | 44 | 56.8 | 0 |
| 1765023431 | 1325 | 76 | 42.9 | 56.9 | 0 |
| 1765022795 | 1327 | 76 | 42.9 | 56.9 | 0 |
| 1765022230 | 1325 | 76 | 43.5 | 56.9 | 0 |
| 1765021595 | 1327 | 75.9 | 43.5 | 56.9 | 0 |
| 1765021031 | 1327 | 76.1 | 43.5 | 57 | 0 |
| 1765020395 | 1324 | 76.1 | 43.5 | 57.1 | 0 |
| 1765019830 | 1324 | 76.1 | 44 | 57 | 0 |
| 1765019196 | 1328 | 76.2 | 44 | 57.1 | 0 |
| 1765018630 | 1327 | 76.2 | 43.5 | 57.1 | 0 |
| 1765017995 | 1327 | 76.2 | 44 | 57.2 | 0 |
| 1765017432 | 1328 | 76.2 | 44 | 57.1 | 0 |
| 1765016795 | 1327 | 76.2 | 44 | 57 | 0 |
| 1765016230 | 1330 | 76.3 | 43.5 | 57 | 0 |
| 1765015595 | 1330 | 76.3 | 44 | 57.1 | 0 |
*Used Equation Coefficients:
DC: 0, 1, 1000
PC Board: 0, 0.1, 0
CPU: 0, 0.1, 0
Ambient: 0, 0.1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)