This is the latest recevied telemetry packets stored in our database for station/object SV2HZE-9. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Voltage* | Celsius* | Rel_Hum* | Atm_Press* | GAS* |
|---|---|---|---|---|---|
| 1785944070 | 4.04 VDC | 35.5 C | 15.47 % | 1018.38 hPa | 59.28 % |
| 1785943615 | 4.04 VDC | 36.3 C | 14.89 % | 1018.25 hPa | 55.76 % |
| 1785938267 | 4.03 VDC | 42.3 C | 14.01 % | 1019.25 hPa | 44.05 % |
| 1785936533 | 3.98 VDC | 43.9 C | 14.86 % | 1022.5 hPa | 36.98 % |
| 1785931339 | 3.98 VDC | 37 C | 17.23 % | 1021.38 hPa | 47.72 % |
| 1785930964 | 3.98 VDC | 38.6 C | 17.36 % | 1019.63 hPa | 43.23 % |
| 1785929543 | 3.93 VDC | 44.2 C | 17.55 % | 1020.88 hPa | 28.94 % |
| 1785917519 | 3.9 VDC | 39.1 C | 18.98 % | 1022.25 hPa | 44.52 % |
| 1785917188 | 3.9 VDC | 40.6 C | 19.31 % | 1022.75 hPa | 43.14 % |
| 1785916406 | 3.88 VDC | 39 C | 20.16 % | 1023 hPa | 44.05 % |
| 1785915979 | 3.87 VDC | 38.1 C | 20.86 % | 1021.13 hPa | 43.63 % |
| 1785914607 | 3.83 VDC | 36.8 C | 23.25 % | 1028.5 hPa | 40.9 % |
| 1785914395 | 3.82 VDC | 36.6 C | 23.59 % | 1030.25 hPa | 40.19 % |
| 1785914141 | 3.81 VDC | 37.1 C | 24.05 % | 1025 hPa | 38.91 % |
| 1785913797 | 3.8 VDC | 38 C | 24.09 % | 1021.88 hPa | 36.18 % |
| 1785913442 | 3.79 VDC | 38.3 C | 24.9 % | 1022.63 hPa | 34.25 % |
| 1785912983 | 3.75 VDC | 35.1 C | 27.75 % | 1024.38 hPa | 34.68 % |
| 1785912530 | 3.72 VDC | 33.6 C | 30.27 % | 1022.5 hPa | 32.04 % |
*Used Equation Coefficients:
Voltage: 0, 0.01, 0
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
GAS: 0, 0.01, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)