This is the latest recevied telemetry packets stored in our database for station/object SV6DBG-7. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Celsius* | Rel_Hum* | Atm_Press* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1780622883 | 28.7 C | 35.71 % | 1021.5 hPa | 0 | 0 |
| 1780613853 | 29 C | 36.33 % | 1021.13 hPa | 0 | 0 |
| 1780604823 | 29.7 C | 39.09 % | 1022.13 hPa | 0 | 0 |
| 1780595793 | 29.6 C | 37.07 % | 1020.38 hPa | 0 | 0 |
| 1780589965 | 24.8 C | 45.57 % | 1020.38 hPa | 0 | 0 |
| 1780589565 | 25.5 C | 40.99 % | 1018.75 hPa | 0 | 0 |
| 1780589134 | 25.9 C | 39.28 % | 1020.38 hPa | 0 | 0 |
| 1780588553 | 27 C | 36.1 % | 1020 hPa | 0 | 0 |
| 1780588137 | 29.7 C | 34.53 % | 1019.38 hPa | 0 | 0 |
| 1780583496 | 24.6 C | 48.01 % | 1015.13 hPa | 0 | 0 |
| 1780583123 | 24.5 C | 47.69 % | 1014.88 hPa | 0 | 0 |
| 1780581778 | 28.6 C | 36.55 % | 1020.38 hPa | 0 | 0 |
| 1780574533 | 30.7 C | 36.25 % | 1020.63 hPa | 0 | 0 |
| 1780570413 | 32.7 C | 40.32 % | 1019.88 hPa | 0 | 0 |
| 1780570035 | 32 C | 41.69 % | 1020.75 hPa | 0 | 0 |
| 1780569333 | 31.8 C | 40.78 % | 1020.5 hPa | 0 | 0 |
| 1780568567 | 30.4 C | 37.73 % | 1021.13 hPa | 0 | 0 |
*Used Equation Coefficients:
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)