This is the latest recevied telemetry packets stored in our database for station/object IU1BOT-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | V_Batt* | Value2* | Value3* | Value4* | Value5* |
---|---|---|---|---|---|
1732722498 | 3.8 VDC | 0 | 0 | 0 | 0 |
1732722196 | 3.81 VDC | 0 | 0 | 0 | 0 |
1732721590 | 3.81 VDC | 0 | 0 | 0 | 0 |
1732720694 | 3.82 VDC | 0 | 0 | 0 | 0 |
1732720391 | 3.83 VDC | 0 | 0 | 0 | 0 |
1732720088 | 3.83 VDC | 0 | 0 | 0 | 0 |
1732719785 | 3.83 VDC | 0 | 0 | 0 | 0 |
1732719179 | 3.83 VDC | 0 | 0 | 0 | 0 |
1732718876 | 3.84 VDC | 0 | 0 | 0 | 0 |
1732718573 | 3.84 VDC | 0 | 0 | 0 | 0 |
1732718271 | 3.84 VDC | 0 | 0 | 0 | 0 |
1732717967 | 3.85 VDC | 0 | 0 | 0 | 0 |
1732705769 | 3.97 VDC | 0 | 0 | 0 | 0 |
1732705466 | 3.97 VDC | 0 | 0 | 0 | 0 |
1732705163 | 3.97 VDC | 0 | 0 | 0 | 0 |
1732704860 | 3.98 VDC | 0 | 0 | 0 | 0 |
1732698625 | 3.99 VDC | 0 | 0 | 0 | 0 |
1732698060 | 4 VDC | 0 | 0 | 0 | 0 |
1732694696 | 4.04 VDC | 0 | 0 | 0 | 0 |
1732694091 | 4.04 VDC | 0 | 0 | 0 | 0 |
1732693788 | 4.04 VDC | 0 | 0 | 0 | 0 |
1732693484 | 4.05 VDC | 0 | 0 | 0 | 0 |
1732693181 | 4.05 VDC | 0 | 0 | 0 | 0 |
1732692878 | 4.05 VDC | 0 | 0 | 0 | 0 |
1732692575 | 4.06 VDC | 0 | 0 | 0 | 0 |
*Used Equation Coefficients:
V_Batt: 0, 0.01, 0
Value2: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)