This is the latest recevied telemetry packets stored in our database for station/object VK2VE-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Value1* | Value2* | Value3* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1785809631 | 475 | 621 | 0 | 0 | 0 |
| 1785809394 | 467 | 619 | 0 | 0 | 0 |
| 1785808755 | 476 | 615 | 0 | 0 | 0 |
| 1785808746 | 474 | 614 | 0 | 0 | 0 |
| 1785808633 | 475 | 613 | 0 | 0 | 0 |
| 1785808338 | 475 | 608 | 0 | 0 | 0 |
| 1785808249 | 469 | 606 | 0 | 0 | 0 |
| 1785808248 | 469 | 606 | 0 | 0 | 0 |
| 1785808163 | 426 | 605 | 0 | 0 | 0 |
| 1785806115 | 475 | 615 | 0 | 0 | 0 |
| 1785805790 | 475 | 612 | 0 | 0 | 0 |
| 1785805673 | 468 | 610 | 0 | 0 | 0 |
| 1785805482 | 469 | 607 | 0 | 0 | 0 |
| 1785805404 | 468 | 605 | 0 | 0 | 0 |
| 1785805181 | 469 | 601 | 0 | 0 | 0 |
| 1785805083 | 467 | 599 | 0 | 0 | 0 |
| 1785798495 | 471 | 623 | 0 | 0 | 0 |
| 1785798430 | 471 | 622 | 0 | 0 | 0 |
| 1785798394 | 475 | 622 | 0 | 0 | 0 |
| 1785798357 | 475 | 621 | 0 | 0 | 0 |
| 1785798244 | 474 | 619 | 0 | 0 | 0 |
| 1785798169 | 475 | 617 | 0 | 0 | 0 |
| 1785797241 | 475 | 600 | 0 | 0 | 0 |
| 1785796688 | 475 | 588 | 0 | 0 | 0 |
| 1785796590 | 474 | 585 | 0 | 0 | 0 |
*Used Equation Coefficients:
Value1: 0, 1, 0
Value2: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)