This is the latest recevied telemetry packets stored in our database for station/object YO3TCO-2. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | V_Batt* | Value2* | Value3* | Value4* | Value5* |
---|---|---|---|---|---|
1732504564 | 4.31 VDC | 0 | 0 | 0 | 0 |
1732502764 | 4.4 VDC | 0 | 0 | 0 | 0 |
1732500964 | 4.43 VDC | 0 | 0 | 0 | 0 |
1732499164 | 4.4 VDC | 0 | 0 | 0 | 0 |
1732497364 | 4.74 VDC | 0 | 0 | 0 | 0 |
1732495564 | 4.4 VDC | 0 | 0 | 0 | 0 |
1732493764 | 4.79 VDC | 0 | 0 | 0 | 0 |
1732491964 | 4.31 VDC | 0 | 0 | 0 | 0 |
1732490163 | 4.31 VDC | 0 | 0 | 0 | 0 |
1732488363 | 4.5 VDC | 0 | 0 | 0 | 0 |
1732486563 | 4.4 VDC | 0 | 0 | 0 | 0 |
1732484763 | 4.21 VDC | 0 | 0 | 0 | 0 |
1732482963 | 4.61 VDC | 0 | 0 | 0 | 0 |
1732481163 | 4.64 VDC | 0 | 0 | 0 | 0 |
1732479363 | 4.19 VDC | 0 | 0 | 0 | 0 |
1732477563 | 4.34 VDC | 0 | 0 | 0 | 0 |
1732475763 | 4.28 VDC | 0 | 0 | 0 | 0 |
1732473963 | 4.41 VDC | 0 | 0 | 0 | 0 |
1732472163 | 4.81 VDC | 0 | 0 | 0 | 0 |
1732470362 | 4.32 VDC | 0 | 0 | 0 | 0 |
1732468562 | 4.31 VDC | 0 | 0 | 0 | 0 |
1732466762 | 4.22 VDC | 0 | 0 | 0 | 0 |
1732464962 | 4.51 VDC | 0 | 0 | 0 | 0 |
1732463162 | 4.67 VDC | 0 | 0 | 0 | 0 |
1732461362 | 4.46 VDC | 0 | 0 | 0 | 0 |
*Used Equation Coefficients:
V_Batt: 0, 0.01, 0
Value2: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)