This is the latest recevied telemetry packets stored in our database for station/object F4IZM-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1785825807 | 142 Count | 405 Count | 115 Count | 0 VDC | 0 VDC |
| 1785824002 | 134 Count | 386 Count | 108 Count | 0 VDC | 0 VDC |
| 1785822197 | 128 Count | 370 Count | 103 Count | 0 VDC | 0 VDC |
| 1785820392 | 123 Count | 355 Count | 99 Count | 0 VDC | 0 VDC |
| 1785818587 | 119 Count | 343 Count | 96 Count | 0 VDC | 0 VDC |
| 1785816782 | 114 Count | 330 Count | 92 Count | 0 VDC | 0 VDC |
| 1785814977 | 109 Count | 314 Count | 88 Count | 0 VDC | 0 VDC |
| 1785813172 | 104 Count | 298 Count | 84 Count | 0 VDC | 0 VDC |
| 1785811367 | 100 Count | 280 Count | 81 Count | 0 VDC | 0 VDC |
| 1785809562 | 95 Count | 263 Count | 77 Count | 0 VDC | 0 VDC |
| 1785807757 | 90 Count | 246 Count | 73 Count | 0 VDC | 0 VDC |
| 1785805952 | 85 Count | 230 Count | 69 Count | 0 VDC | 0 VDC |
| 1785804146 | 80 Count | 214 Count | 65 Count | 0 VDC | 0 VDC |
| 1785802341 | 75 Count | 200 Count | 61 Count | 0 VDC | 0 VDC |
| 1785800537 | 70 Count | 184 Count | 57 Count | 0 VDC | 0 VDC |
| 1785798732 | 65 Count | 171 Count | 53 Count | 0 VDC | 0 VDC |
| 1785796927 | 61 Count | 161 Count | 50 Count | 0 VDC | 0 VDC |
| 1785795122 | 56 Count | 146 Count | 46 Count | 0 VDC | 0 VDC |
| 1785793317 | 51 Count | 131 Count | 42 Count | 0 VDC | 0 VDC |
| 1785791512 | 46 Count | 115 Count | 38 Count | 0 VDC | 0 VDC |
| 1785789707 | 41 Count | 100 Count | 34 Count | 0 VDC | 0 VDC |
| 1785787902 | 36 Count | 84 Count | 30 Count | 0 VDC | 0 VDC |
| 1785786097 | 30 Count | 65 Count | 25 Count | 0 VDC | 0 VDC |
| 1785784292 | 24 Count | 44 Count | 20 Count | 0 VDC | 0 VDC |
| 1785782487 | 19 Count | 34 Count | 16 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)