This is the latest recevied telemetry packets stored in our database for station/object VK2HFF-9. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Temp* | CoreTemp* | Fan* | BattV* | Current* |
---|---|---|---|---|---|
1740134128 | 22 Deg.C | 53 Deg.C | 0 DutyCyc | 12.3 V | 329 mA |
1740132327 | 22 Deg.C | 53 Deg.C | 0 DutyCyc | 12.3 V | 323 mA |
1740130527 | 23 Deg.C | 55 Deg.C | 0 DutyCyc | 12.3 V | 325 mA |
1740128727 | 23 Deg.C | 56 Deg.C | 0 DutyCyc | 12.3 V | 326 mA |
1740126927 | 24 Deg.C | 56 Deg.C | 0 DutyCyc | 12.3 V | 330 mA |
1740125127 | 25 Deg.C | 59 Deg.C | 0 DutyCyc | 12.4 V | 330 mA |
1740123328 | 26 Deg.C | 62 Deg.C | 0 DutyCyc | 12.4 V | 342 mA |
1740121526 | 27 Deg.C | 65 Deg.C | 0 DutyCyc | 12.5 V | 333 mA |
1740119727 | 28 Deg.C | 64 Deg.C | 0 DutyCyc | 12.6 V | 338 mA |
1740117927 | 28 Deg.C | 64 Deg.C | 0 DutyCyc | 12.7 V | 333 mA |
1740116126 | 29 Deg.C | 67 Deg.C | 0 DutyCyc | 12.8 V | 337 mA |
1740114327 | 30 Deg.C | 67 Deg.C | 0 DutyCyc | 12.8 V | 334 mA |
1740112527 | 30 Deg.C | 68 Deg.C | 0 DutyCyc | 12.8 V | 337 mA |
1740110728 | 30 Deg.C | 67 Deg.C | 0 DutyCyc | 13.1 V | 327 mA |
1740108927 | 32 Deg.C | 67 Deg.C | 2 DutyCyc | 12.9 V | 330 mA |
1740107127 | 31 Deg.C | 68 Deg.C | 0 DutyCyc | 12.9 V | 339 mA |
1740105328 | 32 Deg.C | 69 Deg.C | 0 DutyCyc | 13 V | 330 mA |
1740103527 | 32 Deg.C | 69 Deg.C | 0 DutyCyc | 13 V | 328 mA |
1740101727 | 32 Deg.C | 69 Deg.C | 0 DutyCyc | 13.2 V | 327 mA |
1740101478 | 32 Deg.C | 70 Deg.C | 0 DutyCyc | 13.6 V | 328 mA |
1740099677 | 30 Deg.C | 67 Deg.C | 0 DutyCyc | 13.4 V | 319 mA |
1740097877 | 29 Deg.C | 66 Deg.C | 0 DutyCyc | 13.1 V | 320 mA |
1740096077 | 27 Deg.C | 65 Deg.C | 0 DutyCyc | 13 V | 321 mA |
1740094277 | 26 Deg.C | 64 Deg.C | 0 DutyCyc | 13.2 V | 317 mA |
1740092478 | 24 Deg.C | 58 Deg.C | 0 DutyCyc | 13.3 V | 304 mA |
*Used Equation Coefficients:
Temp: 0, 1, 0
CoreTemp: 0, 1, 0
Fan: 0, 1, 0
BattV: 0, 0.1, 0
Current: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)